Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1044418.015
Citation: 01022B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/13/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/09/2016
Gravity: 1
Report ID: 0419700
Contest Date:
Final Order: 09/08/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/08/2015 | $0.00 | 03/09/2016 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $0.00 | 09/01/2015 | Serious |
Text For Citation: 01 Item/Group: 022B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. On or about March 3, 2015, the belt drive for the number 1 ammonia condenser was not guarded to protect employees walking on the condenser cat walk, exposing employees to an amputation hazard at the ingoing nip point. b. On or about March 3, 2015, the belt drive for the ventilation fan in the processing area was not guarded to protect employees walking on the catwalk above the blast freezers, exposing employees to an amputation hazard at the ingoing nip point.