Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1044418.015
Citation: 01021
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $1,120.00
Issuance Date: 08/13/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/09/2016
Gravity: 5
Report ID: 0419700
Contest Date:
Final Order: 09/08/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/08/2015 | $1,120.00 | 03/09/2016 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $2,800.00 | 09/01/2015 | Serious |
Text For Citation: 01 Item/Group: 021 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a. On or about March 3, 2015, in the processing building next to the catwalk above the number 2 freezer, the ventilation fan blades were not guarded, exposing an employee to an amputation hazard.