Violation Detail
Standard Cited: 19100305 G02 III Wiring methods, components, and equipment for general use.
Inspection Nr: 448973.015
Citation: 01020C
Citation Type: Serious
Abatement Date: 12/19/2012 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/16/2012
Nr Instances: 4
Nr Exposed: 12
Related Event Code (REC):
Gravity: 5
Report ID: 0728500
Contest Date: 12/10/2012
Final Order: 02/27/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/27/2014 | $0.00 | 12/19/2012 | Serious | |
Penalty | C: Contested | 01/17/2013 | $0.00 | 12/19/2012 | Serious | |
Penalty | Z: Issued | 11/16/2012 | $0.00 | 12/19/2012 | Serious |
Text For Citation: 01 Item/Group: 020C Hazard:
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) The foot pedal that was located to the east of the Brewco Band Saw did not have a strain relief and wire connector at the pedal end of the electrical cord; (b) The foot pedal that was located to the east of the Brewco Band Saw did not have a strain relief at the box end opposite of the foot pedal; (c) Other wiring entering the box located on the floor below the roller casing east of the Brewco Band Saw were not protected by strain relief; and (d) A switch in an outlet box was hanging by the wiring and not protected from damage by some form of strain relief.