Violation Detail
Standard Cited: 19101027 C Cadmium
Inspection Nr: 314662677
Citation: 01020A
Citation Type: Serious
Abatement Status: X
Initial Penalty:
Current Penalty:
Issuance Date: 07/28/2011
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 07/30/2013
Gravity: 05
Report ID: 0830500
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 02/13/2013 | 07/30/2013 | Serious | ||
| Penalty | Z: Issued | 07/28/2011 | 11/28/2011 | Serious |
Text For Citation: 01 Item/Group: 020A Hazard: CHEMNEP
29 CFR 1910.1027(c): The employer did not ensure that no employee was exposed to an airborne concentration of cadmium in excess of five micrograms per cubic meter of air (5ug/m3), calculated as an eight-hour time-weighted average (TWA): (a)Hill Air Force Base, at 7290 Weiner Street, Hill Air Force Base, UT: On 3/3/11, Hill Air Force Base did not ensure that no employee was exposed to an airborne concentration of cadmium in excess of five micrograms per cubic meter of air (5ug/m3), calculated as an eight-hour time-weighted average (TWA). One employee abrasively blasted aircraft parts in Building 507J4. The metal treatment contained cadmium. This process generated cadmium dust. On 3/3/11 one employee was exposed to cadmium at a concentration greater than the 8 hour Time Weighted Average (TWA) Permissible Exposure Limit (PEL) of 0.005 mg/m3. The employee was exposed to cadmium at a concentration of 0.0663 mg/m3 as an 8 hour TWA. This is 13.27 times the PEL. Air monitoring was conducted for 374 minutes. (b)Hill Air Force Base, at 7290 Weiner Street, Hill Air Force Base, UT: On 3/3/11, Hill Air Force Base did not ensure that no employee was exposed to an airborne concentration of cadmium in excess of five micrograms per cubic meter of air (5ug/m3), calculated as an eight-hour time-weighted average (TWA). One employee abrasively blasted generators and small parts in Building 843B1. The metal treatment contained cadmium. This process generated cadmium dust. On 3/3/11 one employee was exposed to cadmium at a concentration greater than the 8 hour Time Weighted Average (TWA) Permissible Exposure Limit (PEL) of 0.005 mg/m3. The employee was exposed to cadmium at a concentration of 0.1871 mg/m3 as an 8 hour TWA. This is 37.40 times the PEL. Air monitoring was conducted for 265 minutes. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter").-Certification
Translate