Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 983333.015
Citation: 01019B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/06/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/12/2015
Gravity: 5
Report ID: 0627510
Contest Date:
Final Order: 01/29/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/29/2015 | $0.00 | 01/12/2015 | Serious | |
Penalty | Z: Issued | 01/06/2015 | $0.00 | 01/12/2015 | Serious |
Text For Citation: 01 Item/Group: 019B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about July 8, 2014, employees were exposed to caught in hazards in that the employer did not provide any guards on the pulley system on the cement mixer.