Violation Detail
Standard Cited: 19100266 H02 VII Logging operations.
This violation item has been deleted.
Inspection Nr: 448973.015
Citation: 01019
Citation Type: Serious
Abatement Date: 12/11/2012 2
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 11/16/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0728500
Contest Date: 12/10/2012
Final Order: 02/27/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/27/2014 | $0.00 | 12/11/2012 | Serious | |
Penalty | C: Contested | 01/17/2013 | $2,800.00 | 12/11/2012 | Serious | |
Penalty | Z: Issued | 11/16/2012 | $2,800.00 | 12/11/2012 | Serious |
Text For Citation: 01 Item/Group: 019 Hazard:
29 CFR 1910.266(h)(2)(vii): The backcut was not above the level of the horizontal facecut in order to provide an adequate platform to prevent kickback: (a) The feller did not make a back cut that was above the level of the undercut so that the tree would not kick back upon falling.