Violation Detail
Standard Cited: 19100219 E03 II Mechanical power-transmission apparatus.
Inspection Nr: 1068975.015
Citation: 01018B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/04/2015
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0524500
Contest Date: 12/22/2015
Final Order: 06/30/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/30/2016 | $0.00 | Serious | ||
Penalty | C: Contested | 01/07/2016 | $0.00 | Serious | ||
Penalty | Z: Issued | 12/04/2015 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 018B Hazard:
29 CFR 1910.219(e)(3)(ii): Guards for inclined belts were not arranged in such a manner that a minimum clearance of seven (7) feet is maintained between belt and floor at any point outside of guard. Employees were exposed to injuries from rotating parts and ingoing nip points because vertical and inclined belt(s), located seven feet or less from the floor level, were not guarded with a guard that extended to at least fifteen inches above the belt. Employees were exposed to injuries from rotating parts and ingoing nip points because an exhaust fan used in the spray room had an unguarded belt and pulley.