Violation Detail
Standard Cited: 19100255 E Resistance welding.
Inspection Nr: 1655395.015
Citation: 01017B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/07/2023
Nr Instances: 1
Nr Exposed: 40
Abatement Date: 09/19/2023
Gravity: 10
Report ID: 0317700
Contest Date: 09/29/2023
Final Order: 05/27/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/27/2024 | $0.00 | 09/19/2023 | Serious | |
Penalty | C: Contested | 10/25/2023 | $0.00 | 09/19/2023 | Serious | |
Penalty | Z: Issued | 09/07/2023 | $0.00 | 09/19/2023 | Serious |
Text For Citation: 01 Item/Group: 017B Hazard:
29 CFR 1910.255(e): Periodic inspections were not made by qualified maintenance personnel, and a certification record was not maintained. The operator was not instructed to report any equipment defects to his supervisor and the use of the equipment was not discontinued until safety repairs were completed: a) Production Areas: The employer did not implement a program that included inspections by a qualified person and a certification record to identify damage to welding equipment, which resulted in employee exposure to shock hazards from damaged cables exposing bare conductors, on or about March 8, 2023. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED