Violation Detail
Standard Cited: 19100146 D03 Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 313130833
Citation: 01017
Citation Type: Serious
Abatement Status: X
Initial Penalty: $4,500.00
Current Penalty:
Issuance Date: 04/16/2010
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 04/29/2010
Gravity: 10
Report ID: 0523300
Contest Date: 05/07/2010
Final Order: 09/06/2011
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/06/2011 | 04/29/2010 | Serious | ||
| Penalty | Z: Issued | 04/16/2010 | $4,500.00 | 04/29/2010 | Serious |
Text For Citation: 01 Item/Group: 017 Hazard: CHEMNEP
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including but not limited to, the requirements specified in 29 CFR 1910.146(d)(3)(i) through 29 CFR 1910.146(d)(3)(vi): The employer did not develop and implement procedures and practices necessary for safe permit space entry into the Renzmann Wash Units in the Wash Area, including but not limited to, specifying acceptable entry conditions; providing each authorized entrant or that employee's authorized representative with the opportunity to observe any monitoring or testing of permit spaces; isolating the permit space; purging, inerting, flushing, or ventilating the permit space as necessary to eliminate or control atmospheric hazards; providing pedestrian, vehicle, or other barriers as necessary to protect entrants from external hazards; and verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry.ized
Translate