Violation Detail
Standard Cited: 19100303 F02 General.
Inspection Nr: 1366023.015
Citation: 01017
Citation Type: Serious
Abatement Date: 05/20/2019 2
Initial Penalty: $8,525.00
Current Penalty: $4,000.00
Issuance Date: 04/03/2019
Nr Instances: 18
Nr Exposed: 100
Related Event Code (REC):
Gravity: 5
Report ID: 0111700
Contest Date: 04/23/2019
Final Order: 04/27/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/27/2022 | $4,000.00 | 05/20/2019 | Serious | |
Penalty | C: Contested | 04/26/2019 | $8,525.00 | 05/20/2019 | Serious | |
Penalty | Z: Issued | 04/03/2019 | $8,525.00 | 05/20/2019 | Serious |
Text For Citation: 01 Item/Group: 017 Hazard:
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Rough Mill, Milling, Plywood Area- Employees operating woodworking equipment were not protected from electrical hazards where overcurrent devices, electric disconnects, and panel boards were not marked or legibly marked to indicate its purpose. The following equipment was not legibly marked to indicate its purpose: 1. Electric disconnect for the MJM Gang Saw 2. Electric disconnect for the feed conveyor after the MJM Gang Saw 3. Electric disconnect for the Dimter saw feed conveyor 4. Electric disconnect and control panel for the hammer mill 5. Circuit breakers in the 220 Volt panel board in the rough mill at the end wall by the exit 6. Electric disconnect for the Electro-Flow RF glue machine 7. Circuit breakers in the 480 Service Disconnect #2 panel board in the mill 8. Circuit breakers in two 480 volt panel boards near the Koch bore and dowel machine 9. Two 600 Volt electric disconnects near the Koch bore and dowel machine 10. Circuit breakers in the 208 volt panel board near the panel saws 11. All the Square D Plug-In Tap Boxes along the busways in the Rough Mill, Mill, and Plywood Area 12. Electric disconnect outside compressor room 13. 480 volt electric disconnects in the compressor room 14. Circuit breakers in the 480 volt panel board in the shipping department near the exit 15. Circuit breakers in the 220 volt panel board in the shipping department near the exit 16. 480 volt electric disconnects mounted on the wall outside the maintenance shop 17. Circuit breakers in the 480 volt PP-1 panel board in the maintenance garage 18. 480 volt electric disconnects in the maintenance garage near the finger joiner