Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1103444.015
Citation: 01016A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,150.00
Current Penalty: $1,890.00
Issuance Date: 11/23/2015
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 12/18/2015
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 12/17/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/17/2015 | $1,890.00 | 12/18/2015 | Serious | |
Penalty | Z: Issued | 11/23/2015 | $3,150.00 | 12/18/2015 | Serious |
Text For Citation: 01 Item/Group: 016A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). On or about 10/27/15, in the production area, ventilation fans had belt and pulleys on motors that were not fully guarded and/or enclosed.