Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1145817.015
Citation: 01016
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,126.00
Current Penalty: $7,126.00
Issuance Date: 10/24/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 12/14/2016
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 11/15/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/15/2016 | $7,126.00 | 12/14/2016 | Serious | |
Penalty | Z: Issued | 10/24/2016 | $7,126.00 | 12/14/2016 | Serious |
Text For Citation: 01 Item/Group: 016 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. On or about May 12, 2016, the employer failed to guard the horizontal shafts in Building 155 B-Line, Column H:10, the white control box exposing employees to caught in hazards. On or about May 12, 2016, the employer failed to guard the horizontal shafts in Building 129, the shafts for the turning rolls.