Violation Detail
Standard Cited: 19100265 C05 II Sawmills.
Inspection Nr: 1100641.015
Citation: 01015C
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/10/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 1
Report ID: 0316400
Contest Date: 04/04/2016
Final Order: 07/18/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/18/2016 | $0.00 | Serious | ||
Penalty | C: Contested | 04/07/2016 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/10/2016 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 015C Hazard:
29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side: (a) Mill Area: On or about October 21, 2015, and times prior, a fixed wooden stairway, 4 foot, 8 inches in height with 7 risers is used to gain access to the back of the mill near stacks of lumber. The stairway is not equipped with a handrail on the open side.