Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1342920.015
Citation: 01015A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,229.00
Current Penalty: $4,140.00
Issuance Date: 02/25/2019
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 11/13/2020
Gravity: 5
Report ID: 0627500
Contest Date: 03/15/2019
Final Order: 09/27/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/27/2020 | $4,140.00 | 11/13/2020 | Serious | |
Penalty | C: Contested | 03/19/2019 | $10,229.00 | 03/07/2019 | Serious | |
Penalty | Z: Issued | 02/25/2019 | $10,229.00 | 03/07/2019 | Serious |
Text For Citation: 01 Item/Group: 015A Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): On or about August 28, 2018, employees are exposed caught-in hazards due to interlocking/meshing gears missing guards in the following instances: a) Outside the production area, interlocking gears to the shelve cooler machine was missing a guard. b) Outside production area, the can conveyor interlocking gears to the shelve cooler machine was missing a guard.