Violation Detail
Standard Cited: 19100179 B05 Overhead and gantry cranes.
Inspection Nr: 314510710
Citation: 01015
Citation Type: Serious
Abatement Status: I
Initial Penalty: $3,443.00
Current Penalty: $1,148.00
Issuance Date: 09/13/2012
Nr Instances: 3
Nr Exposed: 4
Abatement Date: 09/18/2012
Gravity: 05
Report ID: 0855610
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/20/2013 | $1,148.00 | 09/18/2012 | Serious | |
| Penalty | Z: Issued | 09/13/2012 | $3,443.00 | 09/18/2012 | Serious |
Text For Citation: 01 Item/Group: 015 Hazard: REFINERY
1910.179(b)(5) * General requirements - Rated load marking. The rated load of the crane shall be plainly marked on each side of the crane, and if the crane has more than one hoisting unit, each hoist shall have its rated load marked on it or its load block and this marking shall be clearly legible from the ground or floor. Hoists in facility did not have rated load marked. 1. "A" frame not load tested or marked with load limit in Maintenance Shop. 2. "I" beam not load tested or marked with load limit in Knock Engine room. 3. "I" beam not load tested or marked with load limit in Process Unit.