Violation Detail
Standard Cited: 19100305 G02 III Wiring methods, components, and equipment for general use.
Inspection Nr: 1051410.015
Citation: 01015
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $1,000.00
Issuance Date: 09/24/2015
Nr Instances: 8
Nr Exposed: 6
Abatement Date: 10/21/2015
Gravity:
Report ID: 0418400
Contest Date: 10/15/2015
Final Order: 08/08/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/08/2016 | $1,000.00 | 10/21/2015 | Other | |
Penalty | C: Contested | 10/27/2015 | $5,500.00 | 10/21/2015 | Serious | |
Penalty | Z: Issued | 09/24/2015 | $5,500.00 | 10/21/2015 | Serious |
Text For Citation: 01 Item/Group: 015 Hazard:
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Ammo Press, B-line, on or about April 1, 2015, the outer jacket on the 240-volt power cord connected to the panel box that runs the AMO 110M press was withdrawn, exposing the inner conductors and terminals to strain. b) Pail Department, on or about March 31, 2015, the outer jacket on the 110-volt power cord that runs the hoist was withdrawn, exposing the inner conductors and terminals to strain. c) Pail Department, on or about March 31, 2015, the outer jacket on the 480-volt power cord connected to the bottom of the disconnect panel box that runs the PP018A press was withdrawn, exposing the inner conductors and terminals to strain. d) Pail Department, on or about March 31, 2015, the outer jacket on the 240-volt power cord connected to the side of the electrical panel box that run the UN Blanking #2 press was withdrawn, exposing the inner conductors and terminals to strain. e) Pail Department, on or about March 31, 2015, the outer jacket on the 110-volt 4-ply receptacle outlet that runs the portable hand held grinder and drill was withdrawn, exposing the inner conductors and terminals to strain. f) Can Press, on or about March 31, 2015, the outer jacket on the 240-volt air cylinder cables on the #404 Strip Feed Bottom Press was withdrawn, exposing the inner conductors and terminals to strain. g) Ammo Wire Department, on or about March 31, 2015, the outer jacket on the 240-volt power cord connected to the top of the electrical panel box that runs the AM1108 cover link wire form was withdrawn, exposing the inner conductors and terminals to strain. h) Ammo Department, old maintenance shop, on or about April 1, 2015, the outer jacket on the 240-volt power cord connected to the side of the disconnect panel box that runs the Doall Metalmaster Bandsaw was withdrawn, exposing the inner conductors and terminals to strain.