Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 998318.015
Citation: 01014G
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/01/2015
Nr Instances: 4
Nr Exposed: 10
Abatement Date: 05/06/2016
Gravity: 5
Report ID: 0213100
Contest Date: 04/23/2015
Final Order: 01/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/06/2016 | $0.00 | 05/06/2016 | Serious | |
Penalty | C: Contested | 05/07/2015 | $0.00 | 04/20/2015 | Serious | |
Penalty | Z: Issued | 04/01/2015 | $0.00 | 04/20/2015 | Serious |
Text For Citation: 01 Item/Group: 014G Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Tumbler Room - On or about October 3, 2014, a belt on the A Bank tumblers was not guarded exposing employees to caught-in hazards. b) Tumbler Room - On or about October 3, 2014, a belt on the B Bank tumblers was not guarded exposing employees to caught-in hazards. c) Tumbler Room - On or about October 3, 2014, a belt on Lathe 1 was not guarded exposing employees to caught-in hazards. d) Tumbler Room - On or about October 3, 2014, a belt on Lathe 2 was not guarded exposing employees to caught-in hazards.