Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1639153.015
Citation: 01014B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/05/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/31/2023
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 06/30/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/30/2023 | $0.00 | 07/31/2023 | Serious | |
Penalty | Z: Issued | 06/05/2023 | $0.00 | 07/05/2023 | Serious |
Text For Citation: 01 Item/Group: 014B Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves: On or about January 25, 2023, at a facility located at 502 E. Linden Street in Abbotsford, WI; projecting shaft ends, which projected more than one-half the diameter of the shaft, were not guarded by a nonrotating cap or safety sleeve. In RTE-3, at the Drake machines near the heads of Line 7a and 7b, shaft ends projected out more than one-half their diameter and were not guarded by a nonrotating cap or safety sleeve. Employees were exposed to the rotating shaft ends, while working at the machines' control panels, which posed caught-on hazards.