Violation Detail
Standard Cited: 19260502 B03 Fall protection systems criteria and practices.
Inspection Nr: 1228064.015
Citation: 01014B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/28/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/06/2017
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 11/10/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/10/2017 | $0.00 | 10/06/2017 | Serious | |
| Penalty | Z: Issued | 09/28/2017 | $0.00 | 10/06/2017 | Serious |
Text For Citation: 01 Item/Group: 014B Hazard:
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: (a) 205 Young Street: On or about April 24, 2017 and times prior, a 2x4 placed on the front porch landing at 38in. above the landing floor and 7ft. 3in. above grade, was not secured.