Violation Detail
Standard Cited: 19100134 H03 IV Respiratory Protection.
Inspection Nr: 1357199.015
Citation: 01013C
Citation Type: Serious
Abatement Date: 04/24/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/27/2019
Nr Instances: 3
Nr Exposed: 7
Related Event Code (REC):
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 04/22/2019
Emphasis:
Substance: 1480
Substance: 8890
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/22/2019 | $0.00 | 04/24/2019 | Serious | |
Penalty | Z: Issued | 03/27/2019 | $0.00 | 04/24/2019 | Serious |
Text For Citation: 01 Item/Group: 013C Hazard:
29 CFR 1910.134(h)(3)(iv): 29 CFR 1910.134(h)(3)(iv): For respirators maintained for emergency use, the employer did not [A] Certify the respirator by documenting the date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and the serial number or other means of identifying the inspected respirator; and [B] Provide this information on a tag or label that is attached to the storage comparment for the respirator, is kept with the respirator, or is included in the inspection reports stored as paper or electronic files. This information shall be maintained untill replaced following a subsequent certification: On or about October 31, 2018, and times prior thereto, O'Ryan Oil and Gas did not certify the following respirators, maintained for emergency use, by documenting: date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and a serial number or other means of identifying the inspected respirator; and did not provide this information on a tag or label that is attached to the storage compartment for the respirator, is kept with the respirator, or is included in inspection reports stored as paper or electronic files. a. One Self-Contained Breathing Apparatus (SCBA) respirators located in the control room; b. Two Self-Contained Breathing Apparatus (SCBA) respirators located outdoors in the facility; and c. A bottled supplied-air breathing system located adjacent to the knockout drums and flare.