Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100212 B General requirements for all machines.

Inspection Nr: 705259.015

Citation: 01013B

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $4,000.00

Current Penalty: $0.00

Issuance Date: 04/16/2013

Nr Instances: 2

Nr Exposed: 4

Abatement Date: 05/03/2013

Gravity: 5

Report ID: 0936300

Contest Date:

Final Order: 05/06/2013

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 05/06/2013 $0.00 05/03/2013 Serious  
Penalty Z: Issued 04/16/2013 $4,000.00 05/03/2013 Serious  

Text For Citation: 01 Item/Group: 013B Hazard:

29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. On or about January 18, 2013 in the Rebuild Shop: a) A pedestal grinder was not secured to the concrete floor. b) A drill press was sitting permanently on a metal table and not secured or anchored to the table top.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.