Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1050053.015
Citation: 01013B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/30/2015
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 08/30/2015
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 04/26/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/26/2016 | $0.00 | 08/30/2015 | Serious | |
Penalty | Z: Issued | 06/30/2015 | $0.00 | 07/16/2015 | Serious |
Text For Citation: 01 Item/Group: 013B Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a.) On or about March 31, 2015, the Schwartz Chop Saw in the manufacturing area used to cut wood parts was not properly guarded. Employees were exposed to a projected rotating shaft when cleaning around equipment and operating the saw. The shaft was 3 inches long and 1 inch in diameter. b.) On or about March 31, 2015, the Wood Planer in the manufacturing area used to cut wood parts was not properly guarded. Employees were exposed to a rotating vertical shaft when cleaning around equipment and operating the planer. The shaft was 2.25 inches long and 1 inch in diameter.