Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1745840.015
Citation: 01013A
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,518.00
Current Penalty: $14,518.00
Issuance Date: 10/10/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 11/06/2024
Gravity: 10
Report ID: 0625400
Contest Date: 11/06/2024
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 02/12/2025 | $14,518.00 | 11/06/2024 | Serious | |
| Penalty | Z: Issued | 10/10/2024 | $14,518.00 | 11/06/2024 | Serious |
Text For Citation: 01 Item/Group: 013A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Adhesive Department: On or about May 1, 2024, and at times prior thereto, horizontal shafting was not guarded on adhesive spreader #108 and #109 while employees utilized the adhesive spreaders to perform table assembly and cleaning operations.