Violation Detail
Standard Cited: 19100254 D09 I Arc welding and cutting.
Inspection Nr: 1744068.015
Citation: 01013A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,140.00
Current Penalty: $7,605.00
Issuance Date: 10/23/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/19/2024
Gravity: 5
Report ID: 1032500
Contest Date:
Final Order: 11/19/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/19/2024 | $7,605.00 | 11/19/2024 | Serious | |
Penalty | Z: Issued | 10/23/2024 | $10,140.00 | 11/19/2024 | Serious |
Text For Citation: 01 Item/Group: 013A Hazard:
29 CFR 1910.254(d)(9)(i):The supervisor, when informed by the operator of an equipment defect or safety hazard, did not have the use of the equipment discontinued until its safety had been assured: (a) Continuous Improvement Work Area: on or about and at times prior to June 4, 2024, employees operated a Lincoln Electric FLEXTEX 500P S/N U1161106758 welder with damaged work cables. The outer jackets on both work cables were damaged and copper wire was visible near the positive and negative output studs.