Violation Detail
Standard Cited: 19101026 D01
Inspection Nr: 1181492.015
Citation: 01013
Citation Type: Serious
Abatement Date: 06/16/2017 2
Initial Penalty: $8,873.00
Current Penalty: $3,000.00
Issuance Date: 03/03/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 04/11/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/11/2017 | $3,000.00 | 06/16/2017 | Serious | |
Penalty | Z: Issued | 03/03/2017 | $8,873.00 | 03/22/2017 | Serious |
Text For Citation: 01 Item/Group: 013 Hazard:
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) At 355 Paul Avenue in St. Louis, MO 63135 (Fabrication Areas) - On or about 11/03/2016, the employer failed to determine the 8-hour time-weighted average exposure for a TIG welder who was sampled for 422 minutes and had a TWA of 19.0 micrograms per cubic meter of air when non-sampled time was counted as zero exposure. b) At 355 Paul Avenue in St. Louis, MO 63135 (Fabrication Areas) - On or about 11/03/2016, the employer failed to determine the 8-hour time-weighted average exposure for a MIG welder who was sampled for 475 minutes and had a TWA of 7.3 micrograms per cubic meter of air when non-sampled time was counted as zero exposure.