Violation Detail
Standard Cited: 19100219 I02 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1147532.015
Citation: 01013
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,988.00
Current Penalty: $0.00
Issuance Date: 10/27/2016
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/23/2016
Gravity: 5
Report ID: 0213900
Contest Date: 11/16/2016
Final Order: 08/26/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/26/2021 | $0.00 | 11/23/2016 | Serious | |
Penalty | C: Contested | 01/31/2017 | $4,988.00 | 11/23/2016 | Serious | |
Penalty | Z: Issued | 10/27/2016 | $4,988.00 | 11/23/2016 | Serious |
Text For Citation: 01 Item/Group: 013 Hazard:
29 CFR 1910.219(i)(2): Bolt(s), nuts, or setscrews used in shaft coupling(s) extended beyond the flange of the coupling and were not covered with safety sleeve(s): a) Mill department: A rotating shaft for the motor on the Kobe warm-up mill had unguarded bolts that extended beyond the flange of the coupling, on or about 5/16/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.