Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1051410.015
Citation: 01013
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,500.00
Current Penalty: $5,000.00
Issuance Date: 09/24/2015
Nr Instances: 2
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0418400
Contest Date: 10/15/2015
Final Order: 08/08/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/08/2016 | $5,000.00 | Serious | ||
Penalty | C: Contested | 10/27/2015 | $5,500.00 | Serious | ||
Penalty | Z: Issued | 09/24/2015 | $5,500.00 | Serious |
Text For Citation: 01 Item/Group: 013 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Ammo Wire Department - On or about March 31, 2015 and at times prior to, the rotating horizontal shaft on the AM1108 cover link wire form motor was not covered, exposing employees to entanglement and frictional burns. b) Ammo Wire Department - On or about March 31, 2015 and at times prior to, the rotating horizontal shaft on the AM1109 cover link wire form motor was not covered, exposing employees to entanglement and frictional burns.