Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1045342.015
Citation: 01013
Citation Type: Serious
Abatement Date: 09/23/2015 2
Initial Penalty: $3,300.00
Current Penalty: $2,500.00
Issuance Date: 08/27/2015
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 09/17/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/17/2015 | $2,500.00 | 09/23/2015 | Serious | |
Penalty | Z: Issued | 08/27/2015 | $3,300.00 | 09/23/2015 | Serious |
Text For Citation: 01 Item/Group: 013 Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends did not present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. On or about 3/4/15, in the production area at Line 3, the employer did not ensure shaft ends that projected 8 inches in length and had a diameter of 2 inches were encased or covered. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).