Violation Detail
Standard Cited: 19100134 K01 Respiratory Protection.
Inspection Nr: 1117954.015
Citation: 01012F
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/07/2016
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 08/02/2016
Gravity: 10
Report ID: 0418400
Contest Date: 08/08/2016
Final Order: 09/21/2017
Related Event Code (REC):
Emphasis:
Substance: 9010
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/21/2017 | $0.00 | 08/02/2016 | Serious | |
Penalty | C: Contested | 09/07/2016 | $0.00 | 08/02/2016 | Serious | |
Penalty | Z: Issued | 07/07/2016 | $0.00 | 08/02/2016 | Serious |
Text For Citation: 01 Item/Group: 012F Hazard:
29 CFR 1910.134(k)(1): The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii): (a) In Foundry #1, on or about March 30, 2016, respiratory training was not provided for employees required to wear 3M respirators with 2071 P95 filters.