Violation Detail
Standard Cited: 19101027 F02 I Cadmium
Inspection Nr: 1108994.015
Citation: 01012C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/24/2016
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 09/07/2018
Gravity: 10
Report ID: 0215800
Contest Date: 06/16/2016
Final Order: 11/14/2016
Related Event Code (REC):
Emphasis:
Substance: 0491
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $0.00 | 09/07/2018 | Serious | ||
Penalty | P: Petition to Mod Abatement | $0.00 | 02/28/2018 | Serious | ||
Penalty | F: Formal Settlement | 11/14/2016 | $0.00 | 09/15/2016 | Serious | |
Penalty | C: Contested | 06/16/2016 | $0.00 | 08/25/2016 | Serious | |
Penalty | Z: Issued | 05/24/2016 | $0.00 | 08/25/2016 | Serious |
Text For Citation: 01 Item/Group: 012C Hazard:
29 CFR 1910.1027(f)(2)(i): When the permissible exposure limit (PEL) was exceeded, the employer did not establish and implement a written compliance program to reduce employee exposure to cadmium to or below the PEL by means of engineering and work practice controls: a) Patco Area, Strip and Wash Building, on or about 12/1/15: An employee plasma cutting the undercarriage of a rail car was exposed to 6.02 micrograms per cubic meter of cadmium as an 8-hr. time weighted average (TWA), 1.2 times the permissible exposure limit (PEL) of 5 micrograms per cubic meter, during the 413 minute sampling period. A zero increment was included for the 67 minutes not sampled. The employer failed to implement a written compliance program for employees exposed to cadmium above the PEL. Abatement note: Abatement must be done in steps to include use of respirators until effective engineering controls are implemented, developing a plan and use of approved and effective engineering controls to be done in following stages: 1) Employees must be placed in effective and approved respirators while complying with the requirements of an effective respiratory protection program that complies with 29 CFR 1910.134 and includes medical evaluations, fit -testing and training. (30 days) 2) A plan to reduce employee exposures must be submitted with preference of reducing exposures through appropriate engineering controls. (60 days) 3) Appropriate engineering controls such as, but not limited to, local ventilation or portable ventilation units, with verification of their effectiveness must be in place to reduce employee exposures. (90 days) Abatement documentation must be submitted for this item