Violation Detail
Standard Cited: 19101025 F01 II Lead.
Inspection Nr: 1077524.015
Citation: 01012C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/06/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/02/2016
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 01/25/2016
Related Event Code (REC):
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/25/2016 | $0.00 | 02/02/2016 | Serious | |
Penalty | Z: Issued | 01/06/2016 | $0.00 | 02/02/2016 | Serious |
Text For Citation: 01 Item/Group: 012C Hazard:
29 CFR 1910.1025(f)(1)(ii): Respirators for protection against lead were not used or were not provided when engineering and/or work-practice controls were not sufficient to reduce employee exposures to or below the permissible exposure limit: Employees working in the scale house were not provided with respirators while cutting cable containing lead. (a) One scale house worker was exposed to lead at an 8-hour TWA of 0.068 mg/m3 of air, approximately 1.37 times the PEL of 0.050 mg/m3. Sampling was performed for 472 minutes. Zero exposure was assumed for the 8 minute period not sampled; (b) One scale house worker was exposed to lead at an 8-hour TWA of 0.164 mg/m3 of air, approximately 3.27 times the PEL of 0.050 mg/m3. Sampling was performed for 473 minutes. Zero exposure was assumed for the 7 minute period not sampled.