Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1045342.015
Citation: 01012B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/27/2015
Nr Instances: 3
Nr Exposed: 15
Abatement Date: 09/23/2015
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 09/17/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/17/2015 | $0.00 | 09/23/2015 | Serious | |
Penalty | Z: Issued | 08/27/2015 | $0.00 | 09/23/2015 | Serious |
Text For Citation: 01 Item/Group: 012B Hazard:
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s). On 3/9/15, in the production area of Plant 1, rotating vertical shafts were not enclosed completely to prevent contact and injury. Instances include: a Line 16 Melt Pump Drive shaft on upper area of motor - vertical shaft exposed - 5" exposure b Line 4 rotating shaft - 4" exposure c Line 12 motor shaft exposed rotating part - 10" exposure In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).