Violation Detail
Standard Cited: 19100179 H04 Overhead and gantry cranes.
Inspection Nr: 1264724.015
Citation: 01012A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,070.00
Current Penalty: $2,315.00
Issuance Date: 12/07/2017
Nr Instances: 1
Nr Exposed: 14
Abatement Date: 01/04/2018
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 01/09/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/09/2018 | $2,315.00 | 01/04/2018 | Serious | |
Penalty | Z: Issued | 12/07/2017 | $5,070.00 | 01/04/2018 | Serious |
Text For Citation: 01 Item/Group: 012A Hazard:
29 CFR 1910.179(h)(4): The hook was not being used in accordance with manufacturer's specifications and limitations applicable to the operation, training and use in that the latch for the hook had been removed: a) Facility located at 360 Lambs Road, Sewell NJ, Warehouse/Production, A Bay: The hook used on the Reading crane to rig the metal was missing a latch, on or about 9/19/2017. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19