Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1156638.015
Citation: 01012A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,900.00
Current Penalty: $3,920.00
Issuance Date: 08/01/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2016
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 08/23/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/23/2016 | $3,920.00 | 08/26/2016 | Serious | |
Penalty | Z: Issued | 08/01/2016 | $4,900.00 | 08/05/2016 | Serious |
Text For Citation: 01 Item/Group: 012A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about June 20, 2016, in the Corn Process Room, where employees were exposed to a caught-in hazard when working near and walking by machine #6 without a guard on the pulley.