Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1010941.015
Citation: 01012A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,000.00
Current Penalty: $2,800.00
Issuance Date: 05/19/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/15/2015
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 06/10/2015
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/10/2015 | $2,800.00 | 06/15/2015 | Serious | |
Penalty | Z: Issued | 05/19/2015 | $4,000.00 | 06/15/2015 | Serious |
Text For Citation: 01 Item/Group: 012A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about November 20, 2014, employees were exposed to in-running nip point hazards when the pulley and belt on the Hymmen line was not guarded in an area where employees walk and work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.