Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1717900.015
Citation: 01012
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,676.00
Current Penalty: $6,019.00
Issuance Date: 06/17/2024
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 07/19/2024
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 07/10/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/10/2024 | $6,019.00 | 07/19/2024 | Serious | |
Penalty | Z: Issued | 06/17/2024 | $12,676.00 | 07/05/2024 | Serious |
Text For Citation: 01 Item/Group: 012 Hazard:
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven (7) feet or less from floor or working platform was not enclosed with stationary casing(s): a. HK Cooperative, Inc. dba J. H. Routh Packing Company located in Sandusky Ohio: On or about December 21, 2023, the employer did not ensure the powered vertical drive shaft on the Citrate #1 mix tank located in the blood room was properly guarded to protect employees from crushing injuries created by the rotating shaft. b. HK Cooperative, Inc. dba J. H. Routh Packing Company located in Sandusky Ohio: On or about December 21, 2023, the employer did not ensure the powered vertical drive shaft on the Citrate #2 mix tank located in the blood room was properly guarded to protect employees from crushing injuries created by the rotating shaft.