Violation Detail

Standard Cited: 19100305 A02 IX Wiring methods, components, and equipment for general use.

Inspection Nr: 1608381.015

Citation: 01012

Citation Type: Serious

Abatement Status: Not Completed - Employer Out of Business

Initial Penalty: $6,381.00

Current Penalty: $6,381.00

Issuance Date: 01/12/2023

Nr Instances: 5

Nr Exposed: 33

Abatement Date: 02/23/2023

Gravity: 5

Report ID: 1032100

Contest Date: 02/09/2023

Final Order: 08/07/2023

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty J: ALJ Decision 08/07/2023 $6,381.00 02/23/2023 Serious  
Penalty C: Contested 02/09/2023 $6,381.00 02/23/2023 Serious  
Penalty Z: Issued 01/12/2023 $6,381.00 02/23/2023 Serious  

Text For Citation: 01 Item/Group: 012 Hazard:

29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. a) Stateroom 9 - On or about July 20, 2022, and times prior thereto, the employer had provided employees an aluminum shell light fixture for use without grounding, exposing employees to electrical hazards. b) Laundry Room - On or about July 20, 2022, and times prior thereto, incandescent light bulbs used for in a light fixture were not covered to prevent accidental contact, exposing employees to flying projectile hazards. c) Stateroom 11 - On or about September 29, 2022, and times prior thereto, two light fixtures used with incandescent light bulbs were not covered to prevent accidental contact, exposing employees to flying projectile hazards. d) Stateroom 2 - On or about October 25, 2022, and times prior thereto, an incandescent clamp light with aluminum reflective housing was used without cover prevent accidental contact. The fixture was also used without grounding, exposing employees to flying projectiles and electrical hazards. e) Stateroom 8 Storage - On or about October 25, 2022, and times prior thereto, incandescent light bulbs in a lighting fixture were not covered or guarded to prevent from accidental contact, exposing employees to flying projectile hazards.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.