Violation Detail
Standard Cited: 19100334 A02 II Use of equipment.
Inspection Nr: 1197792.015
Citation: 01011B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/08/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/17/2017
Gravity: 5
Report ID: 0524500
Contest Date: 04/06/2017
Final Order: 08/17/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/17/2017 | $0.00 | 03/17/2017 | Serious | |
Penalty | C: Contested | 04/06/2017 | $0.00 | 03/17/2017 | Serious | |
Penalty | Z: Issued | 03/08/2017 | $0.00 | 03/17/2017 | Serious |
Text For Citation: 01 Item/Group: 011B Hazard:
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: On or about December 14, 2016, Quality Pallets, Inc. had employees exposed to electrical hazards from using damaged extension cords, with tears and cuts in the outer insulation, in the Spacer Room, and these extension cords were not removed from service.