Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1059368.015
Citation: 01011B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/22/2015
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 07/15/2016
Gravity: 10
Report ID: 0213900
Contest Date: 10/14/2015
Final Order: 06/03/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 06/03/2016 | $0.00 | 07/15/2016 | Serious | |
Penalty | C: Contested | 10/19/2015 | $0.00 | 10/14/2015 | Serious | |
Penalty | Z: Issued | 09/22/2015 | $0.00 | 10/14/2015 | Serious |
Text For Citation: 01 Item/Group: 011B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: (a) 9000 River Road, Delair, NJ, Foundry: Blocking devices were not installed to prevent the furnace from drifting down while employees entered the pit to clean, occurred on or about 5/13/2015. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.