Violation Detail
Standard Cited: 19261412 F01
Inspection Nr: 1476017.015
Citation: 01011A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,856.00
Current Penalty: $3,856.00
Issuance Date: 10/27/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/23/2020
Gravity: 5
Report ID: 0830400
Contest Date: 11/09/2020
Final Order: 09/20/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/20/2021 | $3,856.00 | 11/23/2020 | Serious | |
Penalty | C: Contested | 12/02/2020 | $3,856.00 | 11/23/2020 | Serious | |
Penalty | Z: Issued | 10/27/2020 | $3,856.00 | 11/23/2020 | Serious |
Text For Citation: 01 Item/Group: 011A Hazard:
29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section: (a)C & C Construction, Inc. at 82 Burlington Northern Santa Fe Railway, Hazel SD 57242: On or about and at times prior to May 22, 2020, the employer did not ensure that the Grove TMS 300 Crane, Model #8435G being used to offload material and remove grain bin equipment was inspected at least every 12 months by a qualified person. The crane was leaking hydraulic fluid. This condition exposed employees to the hazard of improper crane operation.