Violation Detail
Standard Cited: 19100430 C03 I Equipment.
Inspection Nr: 980215.015
Citation: 01011
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 12/09/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/16/2014
Gravity: 10
Report ID: 0418800
Contest Date: 01/02/2015
Final Order: 09/02/2015
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 09/02/2015 | $7,000.00 | 12/16/2014 | Serious | |
Penalty | C: Contested | 01/08/2015 | $7,000.00 | 12/16/2014 | Serious | |
Penalty | Z: Issued | 12/09/2014 | $7,000.00 | 12/16/2014 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.430(c)(3)(i): Umbilical were not marked in 10-foot increments to 100 feet beginning at the diver's end, and in 50-foot increments thereafter: On June 10, 2014, at the above addressed dive site, the employer did not provide the diver with an umbilical that was marked in increments of 10 feet while in the process of removing debris and installing bricks to plug the 42 inch reinforced concrete pipe. The employee was exposed to the hazard of drowning and arterial gas embolism.