Violation Detail

Standard Cited: 19100304 B03 I Wiring design and protection.

Inspection Nr: 1608381.015

Citation: 01011

Citation Type: Serious

Abatement Status: Not Completed - Employer Out of Business

Initial Penalty: $11,167.00

Current Penalty: $11,167.00

Issuance Date: 01/12/2023

Nr Instances: 1

Nr Exposed: 33

Abatement Date: 02/23/2023

Gravity: 10

Report ID: 1032100

Contest Date: 02/09/2023

Final Order: 08/07/2023

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty J: ALJ Decision 08/07/2023 $11,167.00 02/23/2023 Serious  
Penalty C: Contested 02/09/2023 $11,167.00 02/23/2023 Serious  
Penalty Z: Issued 01/12/2023 $11,167.00 02/23/2023 Serious  

Text For Citation: 01 Item/Group: 011 Hazard:

29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel. a) F/V Pacific Producer - On or about July 20, 2022, and times prior thereto, employees used 120 outlet receptacles throughout the vessel which had multiple leaks in roofing, flooring, and was not water-tight. The receptacles installed and used were not GFCI protected exposing employees to electrical hazards.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.