Violation Detail
Standard Cited: 19100184 E01 Slings.
Inspection Nr: 1475785.015
Citation: 01011
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,096.00
Current Penalty: $4,048.00
Issuance Date: 07/20/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/13/2020
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 08/12/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/12/2020 | $4,048.00 | 08/13/2020 | Serious | |
Penalty | Z: Issued | 07/20/2020 | $8,096.00 | 08/13/2020 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: At 4115 S. Johnson Rd, Chanute, KS in the Fab Shop, the employer permitted the use of a alloy steel chain sling without a permanently affixed durable identification stating size, grade, rated capacity, and reach. The sling was attached and used with a CET 1 ton jib crane