Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1366023.015
Citation: 01011
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,525.00
Current Penalty: $4,500.00
Issuance Date: 04/03/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/22/2019
Gravity: 5
Report ID: 0111700
Contest Date: 04/23/2019
Final Order: 04/27/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/27/2022 | $4,500.00 | 04/22/2019 | Serious | |
Penalty | C: Contested | 04/26/2019 | $8,525.00 | 04/22/2019 | Serious | |
Penalty | Z: Issued | 04/03/2019 | $8,525.00 | 04/22/2019 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Milling- Employees operating the Gerhard Koch bore and dowel machine, model SBD-B0NC S/N 8910/4071, were not protected from a severe laceration and amputation hazard where pulleys located at waist height were not guarded.