Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1298689.015
Citation: 01011
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $0.00
Current Penalty: $5,000.00
Issuance Date: 08/22/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/12/2018
Gravity: 10
Report ID: 0523900
Contest Date: 09/18/2018
Final Order: 12/26/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/26/2019 | $5,000.00 | 10/12/2018 | Serious | |
Penalty | C: Contested | 09/20/2018 | $0.00 | 10/12/2018 | Willful | |
Penalty | Z: Issued | 08/22/2018 | $0.00 | 10/12/2018 | Willful |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Water table at plasma arc cutter; The employer did not ensure that all energy isolating devices needed to control the buildup of hazardous gasses were physically located and operated in such a manner as to isolate the hazardous energy source, such as but not limited to, Hydrogen gas from the aluminum cutting process, when employees were engaged in cleaning, maintenance and repair of the water table.