Violation Detail
Standard Cited: 19100305 G02 III Wiring methods, components, and equipment for general use.
Inspection Nr: 1259236.015
Citation: 01011
Citation Type: Serious
Abatement Date: 12/27/2017 2
Initial Penalty: $2,173.00
Current Penalty: $1,000.00
Issuance Date: 11/30/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 1
Report ID: 0522300
Contest Date:
Final Order: 12/21/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/21/2017 | $1,000.00 | 12/27/2017 | Serious | |
Penalty | Z: Issued | 11/30/2017 | $2,173.00 | 12/27/2017 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about August 09, 2017, adequate strain relief was not provided for the wiring that fed into the company's metal cutting band saw (FMB: model -Titan,serial number T00792).