Violation Detail
Standard Cited: 19261101 J01 I Asbestos
Inspection Nr: 1107832.015
Citation: 01011
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,846.00
Issuance Date: 05/09/2016
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 05/13/2016
Gravity: 5
Report ID: 0111500
Contest Date: 06/08/2016
Final Order: 10/21/2019
Related Event Code (REC): C
Emphasis:
Substance: 9933
Substance: 9955
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/21/2019 | $3,846.00 | 05/13/2016 | Serious | |
Penalty | C: Contested | 06/10/2016 | $5,000.00 | 05/13/2016 | Serious | |
Penalty | Z: Issued | 05/09/2016 | $5,000.00 | 05/13/2016 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1926.1101(j)(1)(i): The employer did not establish a decontamination area, consisting of an equipment room, shower area, and clean room in series, adjacent and connected to the regulated area: Note: This requirement applies to Class I operations involving over 25 linear or 10 square feet of thermal system insulation or surfacing containing asbestos-containing material or presumed asbestos-containing material. Jobsite: Employees were performing Class I work and a decontamination area was not established adjacent to and attached to the area.