Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1069945.015
Citation: 01011
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,000.00
Current Penalty: $3,500.00
Issuance Date: 12/09/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 01/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/06/2016 | $3,500.00 | Serious | ||
Penalty | Z: Issued | 12/09/2015 | $5,000.00 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.219(c)(3): Guarding vertical and inclined shafting. Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section. a. At the workplace, in the powder coating area, the cleaning booth tank had a 25 horsepower Baldor industrial motor, model M4103T, with a vertical shaft not fully guarded to prevent accidental contact, exposing employees to a caught-in hazard. The shaft was approximately three feet from the floor level.