Violation Detail
Standard Cited: 19100146 F13 Permit-required confined spaces
Inspection Nr: 1446527.015
Citation: 01010H
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/17/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/23/2020
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 05/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/11/2020 | $0.00 | 04/23/2020 | Serious | |
Penalty | Z: Issued | 04/17/2020 | $0.00 | 04/23/2020 | Serious |
Text For Citation: 01 Item/Group: 010H Hazard:
29 CFR 1910.146(f)(13): The entry permit that documented compliance and authorized entry to a permit space did not identify equipment, such as personal protective equipment, testing equipment, communication equipment, alarm systems, and rescue equipment to be provided: Paper Machine #9- On or about December 2, 2019, employees working inside the Yankee dryer were not protected from burn, asphyxiation, and entrapment hazards where the employer did not identify on the permit the personal protective equipment and rescue equipment utilized by the entrants to the permit required confined space.