Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 314510710
Citation: 01010C
Citation Type: Other
Abatement Status: X
Initial Penalty:
Current Penalty:
Issuance Date: 09/13/2012
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 10/09/2012
Gravity: 05
Report ID: 0855610
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/20/2013 | 10/09/2012 | Other | ||
| Penalty | Z: Issued | 09/13/2012 | 10/09/2012 | Serious |
Text For Citation: 01 Item/Group: 010C Hazard: REFINERY
1910.134(f)(2) * The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. Employer did not ensure that annual fit-testing of respirators for employees were completed. All employees expired Feb 2012.
Translate